Thermal Oxidizer Variable Frequency Drive
ReGen Series Combustion & Main Fan VFD's
VFD OPERATOR INTERFACE

American Environmental Fabrication & Supply uses VFD's on the
main fan and any combustion fans used on the system. These
are controlled by the operator interface, also commonly known as
an Human Machine Interface (HMI) and provides a means for the
Filtercrobe (bio-filtration system),regenerative, catalytic or direct
fired direct thermal oxidizer operator to start and stop the motor
and adjust the fans operating speeds. Additional operator control
functions include switching between manual speed display and
indication percentage of the fan speed or any faults on the VFD
system. A separate VFD operator interface keypad and display
unit is provided on the front of the VFD controller. The keypad and
display are connected to the VFD controller. We provided
integration from the VFD to the Human Interface device on the
front of the control panel.
VFD OPERATION

When an induction motor is connected to a full voltage supply, it draws several times (up to about 3-6 times) its rated
current. As the load accelerates, the available torque usually drops a little and then rises to a peak while the current
remains very high until the motor approaches full speed.

By contrast, when a VFD starts a motor, it initially applies a low frequency and voltage to the motor. The starting
frequency is typically 2 Hz or less. Thus starting at such a low frequency avoids the high inrush current that occurs
when a motor is started by simply applying the utility or main power voltage at a switch. After the start of the VFD, the
applied frequency and voltage are increased at a controlled rate or ramped up to accelerate the load without drawing
excessive current. This starting method typically allows a motor to develop 150% of its rated torque while the VFD is
drawing less than 50% of its rated current in the low speed range. A VFD can be adjusted to produce a steady 150%
starting torque from standstill right up to full speed. However, cooling of the motor is usually not good in the low speed
range. Running at lower speeds even with rated torque for long periods is not possible due to the overheating of the
motor. If continuous operation with high torque is required in low speeds an external fan will be needed.

In principle, the current on the motor side is in direct proportion of the torque that is generated and the voltage on the
motor is in direct proportion of the actual speed, while on the network or PLC side, the voltage is constant, thus the
current on line side is in direct proportion of the power drawn by the motor, that is U.I or CAN where C is torque and N
the speed of the motor.

With a VFD, the stopping sequence is just the opposite as the starting sequence. The frequency and voltage applied
to the motor are ramped down at a controlled rate. When the frequency approaches zero, the motor is shut off. A small
amount of braking torque is available to help decelerate the load a little faster than it would stop if the motor were
simply switched off and allowed to coast. Additional braking torque can be obtained by adding a braking circuit
(resistor controlled by a transistor) to dissipate the braking energy. With 4-quadrants rectifiers (active-front-end), the
VFD is able to brake the load by applying a reverse torque and reverting the energy back to the network.
American Environmental Fabrication & Supply LLC                                                                                                                                                                                                                                        Fax: +1 (918) 772-3536  
18991 S 410 Road Hulbert, OK 74441-1861                                                                                                                                                                                                                                    
info@american-environmental.us   

© 2010 All Rights Reserved.   Visit our
sitemap page for more information or contact the Webmaster.
Air Pollution Control Equipment
American Environmental Fabrication & Supply, LLC
Worldwide Shipping
Call +1 (918) 708 - 1253
Home            Products            Price List              Used Systems              Service             Blog             Links             Contact  Us            About Us
Products
Regenerative Catalytic Oxidizer (RCO)
Regenerative Thermal Oxidizer (RTO)
Direct Fired Thermal Oxidizer (DFTO)
Low NOx Burners <9ppm (NOx)
VOC Concentrator Systems (TSRA)
Nitrogen Rejection System (PSA)
Filtercrobe I Bio-Filtration (GACBF)
Carbon Bed Adsorption Canister (GAC)
Micro Turbine Waste Heat Energy
AgriMicrobe Sales Formula V

Product Inquiry
Product Questionnaire

Services
Service Inquiry
Spent Carbon Reactivation Program
Air Pollution Control Equipment Services

Purchase Plans
Buying and Service Agreement Plans
Rental Plans (Short/Long Term)
Energy Performance Agreement

Services
Service Inquiry
Spent Carbon Reactivation Program
Air Pollution Control Equipment Service

System Information
Equipment Control
Electrical Cost Reduction
Air Pollution Equipment Explosion Protection
Equipment Reliability
Equipment Protection
Reducing Emissions
Programmable Logic Controls
Ceramic Fiber Protection
Ceramic Saddles Usage
Structured Ceramic Heat Media
Extending Equipment Life

Information On Process & Treatment
Buying a Regenerative Thermal Oxidizer
Common Thermal Oxidizer Buying Mistake
Hydrogen Sulfide Reduction
Optimum RTO Operation
Understanding Soil Vapor Extraction
Reducing Costs of VOC Abatement
Wastewater VOC Abatement
Different Types of Thermal Oxidizers
What is a Regenerative Catalytic Oxidizer
The Correct Air Pollution Control Product
Coffee, Rendering, Bakery and Fishmeal
Natural Gas Processing and Oil Refineries
Cement Plant Air Pollution Control
Landfill Gas Requirements & Technology
Controlling Carbon Monoxide Plant Emissions

Photos Thermal Oxidizers
Photos of Air Pollution Control Equipment
Photos of Rebuilt Equipment
Photos of Installation - Relocation Services

Helpful Links
Environmental Organization Links
Environmental AEFS Blog